Where) |
V : Exhaust Velocity of Vacuum Pump(㎥/hr)
T : Suction temperature(℃)
Mw : Moleculat Weight(Kg)
W : Suction Flow Rate(Kg/Hr)
P : Suction Pressure(Torr)
|
Example(1) |
Suction Temperature : 60℃
Suction Temperature : 15 Torr
Suction Flow rate : 10Kg/Hr(Air)
|
Then |
Vair = 10 × 22.4/29 × (273 + 60)/273 × 760/15= 478㎥/hr |
|
|